Engine Auxiliary Components
ISO Certified Quality Assured
2-5 Day Ship In-stock items
3-12M Warranty MOQ 1 piece

12V Fuel Stop Solenoid 16851-60014 – System-Matched for Kubota BX2350D

<p><strong>16851-60014 Stop Solenoid, 12V fuel shutdown type</strong> — compatible with Kubota BX2350D and multiple BX, GR, TG series tractors.</p> <ul> <li>Belongs to the engine auxiliary system; matched voltage and response timing prevent cascading electrical faults during rebuilds</li> <li>Cross-reference numbers 052600-4530, 16851-60015, and variants verified against engine serial ranges</li> <li>Coil burnout often traces to upstream circuit issues — root-cause diagnosis recommended before replacement</li> </ul> <p>Overhaul kit contents and matched auxiliary components verified before dispatch.</p>

MOQ

1 Piece

Lead Time

2-5 Business Days

Shipping

120+ Countries

Warranty

3-12 Months

Compatible Brands

CAT Komatsu Hitachi Volvo Hyundai Doosan Kobelco SANY XCMG

System-Matched Electrical Parameters — verified coil resistance and voltage logic against Kubota BX2350D engine variants before dispatch.

Technical Specifications

Parameter Value
Part Number 16851-60014
Product Type Stop Solenoid
Cross-Reference (reference only) 1685160014, 052600-4530, 052600-4531, 16851-60015, 16851-60010, 16851-60012, 16851-60013
Machine Fitment B7410D, BX1500D, BX1800D, BX1830D, BX1850D, BX1860, BX2230D, BX2350D, BX2360, BX24D, BX25, G1700, G1800, G1900, G2160, GF1800, GR2100, GR2110, GR2120, T1600H, TG1860
Voltage 12V
Functional Type Fuel Shutdown Solenoid, Fuel Cutoff Solenoid
Material Configuration Precision-wound copper coil, brass valve body
Condition New Aftermarket
Warranty 3-12 months against manufacturing defects
Compliance ISO-certified manufacturing

Application Suitability

Engine System Related Components
Fuel Cutoff & Shutdown Circuit Shutdown relays, wiring harness connectors, ignition switch assemblies
Engine Auxiliary System Fuel filters, injection pump seals, governor linkages
Electrical Control Logic Fuses, voltage regulators, alternator output terminals

Why the Correct 12V Fuel Stop Solenoid engine rebuild Prevents Cascading Electrical Faults

Replacing a failed solenoid without diagnosing the upstream voltage fluctuation often leads to repeated coil burnout within weeks.

In the Pearl River Delta region, I frequently see workshops replace a stop solenoid only to have the new unit fail shortly after. The 12V Fuel Stop Solenoid engine rebuild is rarely the root cause; it is usually the victim of a voltage spike from a failing alternator or a corroded ground path. When a BX2350D tractor comes in with a melted coil, swapping the part without checking the charging system simply masks the real fault. [NEED_CITE: electrical system voltage tolerance standards for mobile diesel equipment]

The Role of the Stop Solenoid in the Engine Auxiliary System

This component sits at the intersection of the electrical control logic and the fuel delivery system. When the ignition is turned off, the 12V Fuel Stop Solenoid engine rebuild receives a signal to cut the fuel supply, ensuring a clean and safe engine shutdown. If the internal resistance of the aftermarket unit does not match the specific engine variant's ECU expectations, the machine may refuse to shut down or, conversely, fail to start.

Engine Serial Variants and Cross-Reference Verification

Kubota produced the BX and GR series tractors over many years, introducing subtle changes in the electrical architecture between production batches. A solenoid that physically fits a BX24D might have a different internal resistance specification than one intended for a later BX2360. We verify the exact engine serial number against our cross-reference database—including alternate numbers like 052600-4530 and 16851-60015—to ensure the electrical parameters align with the specific engine build. [NEED_CITE: importance of engine serial number verification in aftermarket parts sourcing]

Interpreting the 12V Specification and Coil Resistance

The "12V" rating indicates the nominal operating voltage, but the critical factor is the coil's resistance (Ohms) and the resulting current draw. A precision-wound copper coil ensures stable magnetic force generation across the operating temperature range. The brass valve body provides corrosion resistance in the humid environments typical of agricultural and municipal works, preventing the valve from sticking in the open or closed position during critical shutdown sequences.

12V Fuel Stop Solenoid engine rebuild structure and terminal configuration

The Hidden Cost of Ignoring Systemic Faults

Installing a new solenoid on a machine with a compromised wiring harness is a temporary fix. The increased resistance in corroded wires can cause voltage drops, leading to weak magnetic engagement and partial fuel cutoff, which damages the injection pump over time. This "reactive" approach to maintenance results in repeated downtime and higher long-term costs compared to a systematic diagnosis of the entire shutdown circuit. [NEED_CITE: diagnostic procedures for diesel engine shutdown circuit failures]

Sourcing Strategy for Engine Rebuild Shops

Our supply chain integrates self-produced lines and qualified sourced partners under a single warranty, ensuring consistency whether you need one unit for a field repair or a batch for a distributor's stock. We provide technical verification of compatibility based on machine models, photographs of the nameplate, or the existing part number. This eliminates the trial-and-error fitment that often delays critical agricultural operations during peak seasons.

Documentation & Verification

  • Commercial Invoice & Packing List: Detailed with specific 16851-60014 references for customs clearance.
  • Compatibility Sheet: Lists verified cross-references (e.g., 052600-4531) marked as reference only.
  • Quality Inspection Record: Includes electrical continuity and resistance test results for each batch.
  • Warranty Terms: Clear 3-12 month coverage against manufacturing defects in the coil and plunger.
  • Packing Photographs: Visual confirmation of the brass body and terminal condition before dispatch.
  • HS Code Support: Accurate classification for international agricultural machinery parts import.

Installation & Rebuild Sequence

  • Cleanliness: Ensure the mounting flange area on the injection pump is free of debris before installing the 16851-60014 unit.
  • Electrical Check: Verify the wiring harness connector pins are not spread or corroded to ensure full voltage delivery.
  • Torque Specification: Tighten the mounting nuts evenly to prevent distortion of the solenoid body or fuel leaks.
  • Functional Test: Cycle the ignition key to verify the plunger retracts fully and fuel flow resumes immediately.
  • System Validation: Run the engine and check for smooth shutdown; investigate any hesitation in the fuel cutoff response.

Inquiry Guidance for System Matching

To ensure the 12V Fuel Stop Solenoid engine rebuild matches your specific engine variant, please provide the full machine model (e.g., BX2350D) and the engine serial number from the nameplate. If the nameplate is worn, a photograph of the existing solenoid's connector type and mounting flange helps us verify the correct internal resistance specification and cross-reference number.

Brass valve body and precision-wound coil detail for fuel cutoff solenoid

Frequently Asked Questions

Q: What engine subsystem does this stop solenoid belong to? A: It is a critical component of the engine auxiliary system, specifically the fuel cutoff circuit. It bridges the electrical control signals from the ignition switch with the mechanical fuel delivery system, ensuring the engine shuts down safely and preventing "run-on" or dieseling after the key is turned off.

Q: Do different production years of the BX2350D use the same part number? A: Not always. Kubota may update the electrical logic or injection pump design across production runs, leading to different internal resistance requirements. We verify the specific engine serial number against our cross-reference database to ensure the 16851-60014 or its alternate references match your machine's exact electrical architecture.

Q: I replaced the solenoid but the engine still stalls intermittently. What else should I check? A: This usually indicates a systemic fault rather than a part failure. Check the upstream wiring harness for voltage drops, inspect the ignition switch contacts for wear, and verify the alternator output stability. A weak ground connection can also cause insufficient magnetic force in the solenoid, leading to partial fuel restriction.

Q: How do I distinguish between the multiple cross-reference numbers like 052600-4530 and 16851-60015? A: These numbers often represent superseded part numbers or manufacturer-specific codes for the same functional component. However, subtle differences in connector shapes or plunger lengths can exist. We use the engine serial number to filter these references and identify the exact variant required for your specific fuel injection pump model.

Q: Can I confirm the fitment before committing to a bulk order for my workshop? A: Yes, we support sample supply for fitment confirmation. You can order a single unit to test the electrical parameters and physical mounting on your specific machine model. This is particularly useful for repair centers managing a mixed fleet of Kubota tractors with varying production dates.

Part Type Engine Auxiliary Components
MOQ 1 Piece
Lead Time 2-5 Business Days (in-stock)
Packaging Export Standard Packaging
Quality ISO Certified Factory
Warranty 3-12 Months
Origin Guangzhou, China
Compatibility CAT, Komatsu, Hitachi, Volvo, Hyundai, Doosan, Kobelco, SANY, XCMG

Shipping Policy

  • ✓ In-stock items dispatched in 2-5 business days
  • ✓ Multiple freight options: Express, Air, Sea
  • ✓ Real-time tracking provided
  • ✓ Ships to 120+ countries worldwide
  • ✓ Export-standard packaging for all items

Warranty & Quality

  • ✓ 3-12 month warranty on all parts
  • ✓ ISO-certified factory partners
  • ✓ Strict QC inspection before dispatch
  • ✓ Zero counterfeit policy -- guaranteed
  • ✓ Optional sample testing for new buyers
More Products

RELATED PARTS

Engine Auxiliary Components

19269-63013 Starter Motor Compatible with Kubota D902 – Engine Grade

<p><strong>19269-63013 Starter Motor</strong> — 12V, 9-tooth drive gear, replacement for Kubota D902, D950, D722E, V1505, and Z602E engines in compact excavators and tractors.</p> <ul> <li>Engineered for system-level engine rebuilds: inspect flywheel ring gear tooth condition, battery health, and charging circuit integrity before installation to prevent repeat failure</li> <li>Serial variants (D902EBH, D902E-BX, D902-E2-BX-2, D902-E3-BX-2) may carry different starter configurations — cross-reference verification against engine nameplate ensures correct fitment</li> <li>Matched electrical and ignition components ship together for complete overhaul jobs</li> </ul> <p>Overhaul kit contents verified item by item before dispatch to match your engine build specification.</p>

View Details
Engine Auxiliary Components

12V Fuel Shut Off Solenoid 365-3339 for CAT Engine – System-Matched

<p><strong>365-3339 Stop Solenoid, 12V, IP67 Sealed</strong> — replacement for CAT engine auxiliary systems on 3011C, 3013C, C1.5, C2.2 and 3024C builds. This solenoid interfaces directly with the fuel injection circuit; ordering alongside matched fuel line seals, gaskets and filters ensures a complete system-level repair. Coil resistance and valve sealing performance verified against rebuild-grade tolerances. - Cross-reference: 217-5204, 419-7640, 271-2117 - Fits skid steer loaders 216–257B and vibratory compactors CB-14 to CB-335E - Overhaul kit contents checked item by item before dispatch</p>

View Details
Engine Auxiliary Components

Throttle Solenoid P12972 | Overhaul Component for Niftylift TD34 SD34 SD50

<p><strong>P12972 Stop Solenoid, 12V DC, 2.8Ω Coil Resistance</strong> — engine auxiliary component compatible with Niftylift TD34, SD34, SD50, and HR series aerial platforms.</p> <ul> <li>Interfaces directly with throttle linkage and ECU driver circuit; matched coil resistance prevents secondary electrical faults during engine rebuilds</li> <li>Root-cause diagnostics recommended: upstream fuel timing or relay issues may cause repeat solenoid failure</li> <li>Supplied as part of system-level engine auxiliary kits alongside gaskets, connectors, and fasteners</li> </ul> <p>Overhaul kit contents verified item-by-item against your specific engine serial before dispatch.</p>

View Details
Cushion Damper

Rubber Mounting 1487116 | Matched Set for Hamm Road Roller Engine

<p><strong>Rubber Mounting 1487116 Cushion Damper, Shore A 65±3, -20°C to +70°C</strong> — replacement for HAMM road rollers including 3205, 3307, 3410–3414, 3516–3520, DV40–DV90, HD90–110, and H-series models. Isolates engine vibration to protect fuel lines, wiring harnesses, and hydraulic hoses from fatigue cracking. Matched damping characteristics prevent over-stiffening or lateral engine movement during compaction work. Paired supply with engine overhaul gasket sets and fasteners keeps rebuild tolerances aligned.</p> <ul> <li>Overhaul kit contents verified item-by-item against your engine serial variant before dispatch</li> </ul>

View Details
Get a Quote

INTERESTED IN
THIS PART?

Send us your inquiry and our technical team will verify the part and provide a competitive quote within 24 hours. MOQ starts from 1 piece.

2h Part Verification
24h Full Quote

Send Your Inquiry

Fill in the form and we'll get back to you within 24 hours.

Response within 24 hours · No commitment required