View Details
<p><strong>Stop Solenoid SBA185206083 — 12V DC, IP67 Sealed</strong> — engine auxiliary component for Shibaura ISM N844 and New Holland TC series tractors. This fuel shut-off solenoid interfaces with the injection pump lever and ignition circuit; check relay, wiring harness, and ignition switch before replacement to address the root cause. Class H winding wire and dual O-ring sealing support reliable operation across agricultural and light construction duty cycles. Overhaul cross-references verified against multiple superseded numbers; matched engine system components ship together for rebuild consistency.</p>
MOQ
1 Piece
Lead Time
2-5 Business Days
Shipping
120+ Countries
Warranty
3-12 Months
Compatible Brands
Engine Sequence Variants Confirmed — Coil resistance and connector type validated against Shibaura ISM N844 serial ranges before dispatch.
| Parameter | Value |
|---|---|
| Part Number | SBA185206083 |
| Product Type | Stop Solenoid |
| Cross-Reference | 185206080, 185206085, 87761614, 281552A1 (reference only) |
| Machine Fitment | New Holland TC18, TC21, TC21D, TC21DA, TC23DA, TC24D, TC24DA, TC25, TC25D, TC26DA, TC29, TC29D, TC29DA, TC30, TC31DA, TC33, TC33D, TC33DA, TC34DA, TC35, TC35A, TC35D, TC35DA, TC40, TC40A, TC40D, TC40DA, TC45, TC45A, TC45D, TC45DA, TC48DA, TC55DA, TT45A, TT50A, TZ18DA, TZ22DA, TZ24DA, TZ25DA, Workmaster 45, Workmaster 55, Boomer Series, T-Series, MC Series |
| Voltage | 12V DC |
| Coil Resistance | 12.2–12.8 Ω at 20°C |
| Wire Class | Class H (180°C) |
| Sealing Rating | IP67 |
| Surface Treatment | Zinc-nickel plating (15 μm) |
| Operating Temperature | –25°C to +105°C |
| Condition | New Aftermarket |
| Warranty | 3–12 months against manufacturing defects |
| MOQ | 1 piece |
| Engine System | Related Components |
|---|---|
| Fuel Shutoff Circuit | Engine stop relay, ignition switch, wiring harness connectors |
| Injection Pump Interface | Shutoff lever linkage, pump mounting gasket, fuel lines |
| Electrical Distribution | Fuses, main relay block, battery terminal connections |
| Engine Auxiliary Cooling | Adjacent sensors and wiring vulnerable to heat soak near solenoid mount |
The solenoid is usually the victim of a wiring fault, not the origin of one.
Field reports from high-altitude mining sites and agricultural regions consistently show stop solenoid replacements failing within the first few hundred hours because the root electrical cause was never isolated. A shorted relay or chafed harness wire forces excess current through the coil until thermal breakdown occurs. Replacing the Stop Solenoid SBA185206083 without checking the full shutdown circuit turns a simple electrical repair into a recurring warranty claim [NEED_CITE: diesel engine electrical fault isolation procedures for auxiliary components].
This stop solenoid belongs to the engine auxiliary system and directly controls the fuel injection pump shutoff lever during ignition-off cycles. It is electrically linked to the stop relay, ignition switch, and main harness connector. When one of these upstream components develops resistance or intermittent contact, the solenoid coil absorbs the excess thermal load and eventually burns out. Correct diagnosis requires measuring voltage drop across the relay contacts and checking the harness for continuity before concluding the solenoid is the failed part.
Multiple OEM reference numbers (185206080, 185206085, 87761614, 281552A1) apply to different production batches and machine variants within the Shibaura ISM N844 and New Holland TC series range. The connector type, mounting flange depth, and plunger stroke length can vary between engine serial blocks even when the base machine model remains the same. Verifying the exact engine serial number prevents receiving a solenoid that physically mounts but fails to engage the shutoff lever correctly [NEED_CITE: engine serial variant identification for fuel system components].
The Class H (180°C) winding wire maintains electromagnetic stability during prolonged high-duty-cycle operation in hot engine bays where ambient temperatures regularly exceed 80°C. The specified coil resistance range of 12.2–12.8 Ω at 20°C confirms correct calibration for the 12V system; a reading outside this window indicates either an internal short or a mismatched unit. The IP67 sealing rating, achieved through dual O-rings and a molded silicone gasket at the mounting interface, prevents wash-down water and diesel mist from reaching the coil windings — a primary failure origin in agricultural environments. The zinc-nickel plating provides corrosion resistance rated beyond 500 hours of salt spray exposure, protecting the housing in coastal and high-humidity operating regions.
A workshop that installs a new stop solenoid without verifying relay health and harness condition will see the replacement fail again, sometimes within weeks. Each repeat failure means another teardown, another gasket, another round of troubleshooting labor, and growing customer frustration. The cumulative cost of two or three misdiagnosed cycles far exceeds the time required to perform a proper circuit check upfront [NEED_CITE: repeat failure cost analysis for diesel engine auxiliary electrical components].
Self-produced and qualified sourced lines operate under the same QC protocol and warranty terms, so every stop solenoid shipped meets identical test standards. Eight product categories — including seals, gaskets, filters, and electrical connectors — allow a complete fuel shutoff circuit repair list to ship as one consignment. Part identification from engine serial number, machine model, or nameplate photograph ensures the correct variant is dispatched. Cross-reference verification covers superseded and alternate numbers, preventing variant mismatches that commonly occur when reference tables are copied between sellers. Sample supply is available for fitment confirmation before committing to bulk orders for fleet rebuild programs. Technical staff can confirm connector type, plunger stroke, and mounting tolerance against specific engine serial data.
To ensure the correct variant is quoted, provide the engine model, engine serial number, and machine model. Photographs of the existing solenoid connector and nameplate help confirm cross-reference applicability and rule out superseded number mismatches. Mentioning any prior rebuild history or recurring electrical faults allows the technical team to advise on adjacent components that should be checked during installation.
Q: What other engine system components should I check when the stop solenoid fails? A: Before replacing the solenoid, test the engine stop relay for contact resistance, check the ignition switch for intermittent operation, and inspect the wiring harness for chafed insulation or corroded pins. A fault in any of these upstream components will send abnormal current through the new solenoid coil and cause repeat failure.
Q: How do I confirm which cross-reference number applies to my specific engine serial? A: The OEM reference numbers 185206080, 185206085, 87761614, and 281552A1 correspond to different production batches and connector configurations. Provide your engine serial number and machine model so the correct variant can be verified against cross-reference records before shipping.
Q: Why did my previous replacement solenoid fail again within a few hundred hours? A: Repeat failure typically indicates an unresolved upstream electrical fault. High resistance in the relay contacts or a partially shorted harness wire forces the coil to operate beyond its thermal rating. Diagnosing the full shutdown circuit, rather than replacing only the solenoid, prevents this pattern.
Q: Does the wiring harness connector type vary between New Holland TC series variants? A: Yes, connector pin configuration and housing shape can differ between early and late production runs within the same TC series model. A photograph of your existing connector, along with the machine serial number, allows accurate variant matching before the replacement is dispatched.
Q: Can I request a sample to verify fitment before ordering for a fleet rebuild program? A: Sample units are available for fitment confirmation against your specific engine serial range. Testing the sample on one machine verifies mounting depth, connector type, and shutoff lever engagement before committing to a bulk order for the entire fleet.
<p>尺寸档次按返修史确认</p>
View Details<p><strong>17531-64012 Alternator 12V 14A</strong> — compatible with Kubota Z482 and D722 engines for auxiliary charging system rebuilds.</p> <ul> <li>Fits Doosan Solar 015 and Kubota generator sets</li> <li>Replaces OEM cross-reference 17531-64010 / 17531-6401-0</li> <li>Class H insulation with Schottky diode rectifier</li> <li>Six-month warranty on manufacturing defects</li> </ul> <p>Paired replacement with belt tensioner and harness terminals prevents repeat charging failures during engine overhaul.</p> <p>Overhaul kit contents verified component-by-component before dispatch.</p>
View Details<p><strong>35DZS1E2 Stop Solenoid, 12V, Copper Winding</strong> — replacement for Deutz 912, 913, and 914 series engines including BFL914, F3L914, and TCD6L91406 variants. Part of the fuel shut-off control system; inspect wiring harness connectors and fuel lines for contamination or voltage spikes that caused the original failure before installing this unit. Cross-reference 04233841 and 04234373 verified for engine serial matching.</p> <ul> <li>Overhaul kit contents checked item by item before dispatch</li> </ul>
View Details<p><strong>6676957/6685190 Starter Motor, 12V 2.7 kW PLGR Type</strong> — compatible with Kubota V2203/V3300 and Bobcat skid steer engines during rebuild and overhaul applications.</p> <ul> <li>Part of the engine auxiliary system; inspect batteries, alternators, ground cables, and flywheel ring gear before installation to prevent repeat cranking failure</li> <li>11-tooth pinion matches original gear pitch; peak draw within OEM electrical limits to protect ECUs</li> <li>Solenoid contacts surface-treated against oxidation for reliable engagement across high-cycle duty</li> </ul> <p>Overhaul kit contents verified item-by-item before dispatch to match your specific engine build variant.</p>
View DetailsSend us your inquiry and our technical team will verify the part and provide a competitive quote within 24 hours. MOQ starts from 1 piece.
Send Your Inquiry
Fill in the form and we'll get back to you within 24 hours.