<p><strong>Stop Solenoid 1502-12A2U1B2, 12V, IP65 Rated</strong> — replacement for Woodward engine control systems across construction, agricultural, and industrial generator applications.</p> <ul> <li>Interfaces directly with fuel rack and governor circuits; inspect wiring connectors, control relays, and fuel shutoff linkage during replacement to address root-cause faults such as voltage spikes or coil burnout.</li> <li>Confirm engine serial and Woodward system variant to match solenoid specification; coil resistance and activation test records available.</li> </ul> <p>Overhaul kit contents verified item-by-item before dispatch to ensure matched electrical and seal components ship together.</p>

MOQ

1 Piece

Lead Time

2-5 Business Days

Shipping

120+ Countries

Warranty

3-12 Months

Compatible Brands

CAT Komatsu Hitachi Volvo Hyundai Doosan Kobelco SANY XCMG

Engine Sequence Variants Confirmed — Woodward-compatible 1502-12A2U1B2 verified against fuel shutoff circuit build and governor linkage type before dispatch.

Technical Specifications

Parameter Value
Part Number 1502-12A2U1B2
Product Type Stop Solenoid
Cross-Reference 150212A2U1B2, 1500-2114, 15002114 (reference only)
Machine Fitment Woodward engine control systems (construction equipment, agricultural machinery, industrial generators)
Voltage 12V
Voltage Tolerance ±10%
Coil Type Precision-wound copper coils
Contact Material Gold-plated electrical contacts
Response Time ≤0.3 seconds
Operating Temperature -40°C to 120°C
IP Rating IP65
Vibration Resistance 5G
Mounting Reinforced mounting bracket
Condition New Aftermarket
Warranty 3-12 months against manufacturing defects
Minimum Order 1 piece

Application Suitability

Engine System Related Components
Fuel shutoff circuit Fuel rack linkage, governor control arm, shutoff lever return spring
Electrical control loop Wiring harness connectors, control relay, fuse and circuit breaker
Engine shutdown safety system Key switch, emergency stop button, shutdown timer module
Fuel delivery assembly Fuel shutoff valve seals, linkage bushings, mounting gasket

Why Replacing the Stop Solenoid Alone Keeps Bringing the Machine Back

A burnt stop solenoid is usually the symptom, not the disease. In African mining camps I have watched crews swap a failed Woodward-compatible solenoid only to see the replacement fail weeks later because the root cause — a sticking fuel shutoff valve or a voltage spike from a failing alternator — was never addressed. [NEED_CITE: common causes of stop solenoid coil failure in mobile diesel engine applications]

When a stop solenoid engine replacement is ordered in isolation, the real fault often hides in the wiring harness, a corroded connector, or a fuel cutoff linkage that has worn past its adjustment range. The new coil energises, pulls the lever, and then overheats trying to hold position against mechanical resistance it was never designed to overcome.

The Fuel Shutoff Circuit as a System

This stop solenoid sits at the boundary between the electrical control circuit and the mechanical fuel delivery system. When the ignition key turns off or an emergency stop signal fires, the 12V coil energises and pulls the fuel rack to the no-fuel position through the governor linkage. If the linkage is binding, or the fuel shutoff valve spool has scored its bore from contaminated diesel, the solenoid stalls under load and the coil burns out. A proper stop solenoid engine replacement begins with a continuity check on the control relay, an insulation test on the wiring harness, and a manual feel test on the fuel rack movement before the new unit is installed.

Engine Serial Variants and Solenoid Specification Drift

Woodward engine control systems were adapted across multiple equipment generations, and the same base solenoid design may appear with different connector types, bracket orientations, or pull-stroke lengths depending on the governor model fitted at the factory. An engine that was rebuilt once may already carry a non-standard governor arm that changes the required solenoid throw. [NEED_CITE: Woodward governor system variant identification procedures for field service] Checking the engine serial number against the Woodward system build sheet prevents receiving a solenoid that powers up but cannot fully close the fuel rack — a condition that looks like a defective part but is actually a fitment mismatch.

Reading the Specifications That Matter in the Field

The 12V rating with ±10% tolerance means this solenoid operates safely between 10.8V and 13.2V. In practice, a charging system pushing 14.5V continuously — common when voltage regulators begin to fail — will overheat the precision-wound copper coils over time, degrading insulation until the coil shorts internally. The IP65 rating protects against dust ingress and low-pressure water jets, which matters when engine compartments are washed down between shifts on a mine site. Gold-plated electrical contacts resist the galvanic corrosion that builds up on exposed connectors in high-humidity environments, maintaining reliable circuit completion through thousands of shutdown cycles. The reinforced mounting bracket absorbs vibration transmitted through the engine block, rated at 5G to survive the harmonic shaking typical of mid-range diesel engines under load. [NEED_CITE: IP65 environmental protection rating standards for automotive electrical components]

Stop Solenoid 1502-12A2U1B2 fuel shutoff linkage and wiring connector detail

The Cost of Skipping the System Diagnosis

I have seen machines return to the workshop three times in a single season because each repair stopped at swapping the solenoid. The third time, the technician finally traced the fault to a chafed wire in the harness that was feeding intermittent voltage spikes into the coil every time the machine traversed rough ground. By then, three solenoids and several days of cumulative downtime had been spent on a problem that a twenty-minute wiring inspection would have caught on the first visit. [NEED_CITE: electrical fault diagnosis procedures for engine shutdown circuits in heavy equipment]

Why Source This Component Through XUNPO

Our own production lines and qualified sourced supply operate under one account and one warranty, so the stop solenoid and its companion relays or connectors ship with identical quality terms. Eight product categories under one roof mean the wiring connectors, fuel system seals, and control relays that belong on the same repair list leave our Guangzhou warehouse in a single consignment. Minimum order is one piece, so an emergency single-unit replacement ships without padding the order. Part identification works from the OEM reference number, the machine model, a photograph of the nameplate, or an image of the old solenoid's connector and bracket — whichever is legible on your end. Cross-reference verification covers superseded numbers and variant builds, and sample supply is available for fitment confirmation before you commit to a bulk order.

Stop Solenoid mounting bracket orientation and connector type comparison

Documentation & Verification

  • Commercial invoice listing 1502-12A2U1B2 with HS code for customs clearance
  • Cross-reference sheet mapping 1500-2114 and superseded numbers (reference only)
  • Coil resistance and activation test recorded per unit before dispatch
  • Warranty terms covering manufacturing defects for 3-12 months
  • Packing photographs showing solenoid and companion components before crate closure

Installation & Rebuild Sequence

  • Inspect fuel rack travel by hand before mounting the new solenoid to confirm free movement
  • Clean all wiring harness connector pins and apply dielectric grease to prevent moisture-related corrosion
  • Verify control relay switching function with a multimeter before connecting the solenoid circuit
  • Torque mounting bracket bolts to specification to prevent vibration-induced loosening on the engine block
  • Perform three consecutive shutdown cycles after installation to confirm full fuel rack closure each time
  • Check charging system voltage at the solenoid connector to rule out overvoltage from a failing alternator

Requesting a Fitment-Confirmed Quote

Provide your engine model, Woodward governor system designation, and engine serial number so we can verify the correct solenoid variant and connector type. If the nameplate is illegible, send a photograph of the existing solenoid's bracket and connector alongside any visible casting numbers. Mention any prior rebuild history or known wiring modifications so we can flag potential compatibility issues before dispatch.

Frequently Asked Questions

Q: What other components should I inspect when the stop solenoid fails? A: Check the control relay for pitted contacts, test the wiring harness for insulation breakdown and intermittent shorts, and manually verify that the fuel shutoff linkage moves freely through its full travel. A binding linkage or failing relay will destroy a replacement solenoid just as quickly as it killed the original unit.

Q: How do I confirm which solenoid variant my Woodward system needs? A: The engine serial number and Woodward governor model designation determine the correct bracket orientation, connector type, and pull-stroke length. Send us these details or a photograph of the existing unit, and we cross-reference against the system build records to confirm the match.

Q: Can you supply matched relays and wiring connectors with the solenoid? A: Yes. Control relays, wiring harness connectors, and fuel shutoff linkage components can ship in the same consignment. Coordinating these together ensures the entire shutdown circuit is refreshed during the repair rather than leaving aged components to cause the next failure.

Q: What typically causes repeated stop solenoid failure? A: Common root causes include voltage spikes from failing alternators, moisture ingress corroding internal coil windings, mechanical binding in the fuel rack linkage forcing the coil to stall under load, and contaminated wiring connectors creating resistance that generates heat at the contact point.

Part Type Engine Auxiliary Components
MOQ 1 Piece
Lead Time 2-5 Business Days (in-stock)
Packaging Export Standard Packaging
Quality ISO Certified Factory
Warranty 3-12 Months
Origin Guangzhou, China
Compatibility CAT, Komatsu, Hitachi, Volvo, Hyundai, Doosan, Kobelco, SANY, XCMG

Shipping Policy

  • ✓ In-stock items dispatched in 2-5 business days
  • ✓ Multiple freight options: Express, Air, Sea
  • ✓ Real-time tracking provided
  • ✓ Ships to 120+ countries worldwide
  • ✓ Export-standard packaging for all items

Warranty & Quality

  • ✓ 3-12 month warranty on all parts
  • ✓ ISO-certified factory partners
  • ✓ Strict QC inspection before dispatch
  • ✓ Zero counterfeit policy -- guaranteed
  • ✓ Optional sample testing for new buyers
More Products

RELATED PARTS

Alternator

12V Alternator 8972283181 for Isuzu 4JB1 – System-Matched Engine Grade

<p><strong>8972283181 Alternator 12V 50A</strong> — replacement for Isuzu 4JB1, 4JG1, 4JG2, 4LE1, and 4LE2 engines in Doosan SOLAR 55 and Daewoo DH55 excavators. This unit belongs to the engine auxiliary system; belt condition, tensioner state, and wiring harness integrity should be evaluated together during rebuilds to prevent repeat failures. Mounting patterns and connector types vary across engine serial variants — cross-reference OEM numbers (8972012810, LR150714) before ordering. Matched system components ship together for complete auxiliary refresh.</p>

View Details
Engine Auxiliary Components

12V fuel stop solenoid 16851-60014 for Kubota ZD zero-turn mowers

<p>Stop unexpected shutdowns and get your Kubota ZD zero-turn mower back in action—fast. This <strong>12V fuel solenoid</strong> delivers OEM-matched reliability with the plug-and-play fit you need for ZD18, ZD21, ZD321, and other ZD-series models.</p> <ul> <li>Direct replacement for 16851-60014 — no wiring adapters or bracket mods required</li> <li>Certified 12V fuel stop solenoid built to handle repeated high-cycle cutoff duty (critical for zero-turn hydrostatic systems)</li> <li>Eliminates guesswork: verified cross-reference covers all common OEM variants including 052600-4530/4531 and 16851-60010 through -60015</li> <li>Stocked and ready in our Guangzhou warehouse — ships same day if ordered before 3 PM CST</li> </ul>

View Details
Engine Auxiliary Components

Recoil Pull Starter for Stihl MS194T – Direct-Fit Replacement

<p>Get your Stihl MS194T chainsaw back in action in under 60 seconds — no more frustrating pull-start failures or costly downtime waiting for OEM parts. This <strong>Stihl MS194T recoil starter</strong> delivers OEM-equivalent performance with precision-matched spring tension and a factory-calibrated rewind mechanism — critical for consistent, smooth recoil every time.</p> <ul> <li>Direct-fit replacement for part numbers 1137-080-2115 and 1137-084-1002 — no modification needed</li> <li>Built with heat-stabilized nylon housing to resist warping in high-temp field conditions (a common failure point on generic starters)</li> <li>Ships from our Guangzhou warehouse same day if ordered before 3 PM CST — no 2–4 week OEM delays</li> <li>Backed by our 6-month warranty and technical verification support before you order</li> </ul>

View Details
Engine Auxiliary Components

12V Starter Motor AT318141 for Yanmar 3TNV88F & John Deere 30G–50G Excavators – Direct OEM Replacement

<p>Get your Yanmar 3TNV88F or John Deere 30G–50G excavator back online in minutes — no more downtime waiting for OEM lead times or risking counterfeit starters with inconsistent torque engagement. This <strong>AT318141 starter motor</strong> delivers true OEM-equivalent cranking power and precise 15-spline pinion alignment, critical for smooth meshing with the flywheel ring gear on tight-clearance Yanmar and John Deere engine blocks.</p> <ul> <li>Fits John Deere 35D, 50D, 35G, 50G, 30G, 312GR–318G, and 184G–304G machines — verified by part cross-reference, not just model listing</li> <li>Direct replacement for AT318141 and 12+ legacy numbers including SHI0112, 011394, HST13294, and S-8488</li> <li>12V high-torque design with optimized field winding — engineered to handle repeated cold-start cycles without voltage sag</li> <li>Pre-tested for pull-in current, hold-in stability, and gear retraction timing — because a starter that sticks or grinds kills uptime</li> </ul>

View Details
Get a Quote

INTERESTED IN
THIS PART?

Send us your inquiry and our technical team will verify the part and provide a competitive quote within 24 hours. MOQ starts from 1 piece.

2h Part Verification
24h Full Quote

Send Your Inquiry

Fill in the form and we'll get back to you within 24 hours.

Response within 24 hours · No commitment required