Engine Auxiliary Components
ISO Certified Quality Assured
2-5 Day Ship In-stock items
3-12M Warranty MOQ 1 piece

12V Fuel Shutoff Solenoid 17454-60010 16616-60010 – Overhaul Component

<p><strong>17454-60010 16616-60010 Stop Solenoid</strong>, 12V, 5 bar pressure rating — compatible with Kubota D905, V1505T and 05-series engines used in B-series tractors and F-series loaders.</p> <ul> <li>Engine auxiliary fuel shutoff system component; inspect injection pump condition, fuel line seals, and ECU shutdown circuit during replacement to address root-cause failures</li> <li>Dual NBR O-ring sealing rated to 120°C; verify engine serial variant against superseded references 16616-60013, 16616-60015, 17594-60014 for correct electrical match</li> <li>Complete overhaul kits and matched fuel system components available for system-level rebuild planning</li> </ul> <p>Overhaul kit contents verified item-by-item against your engine build record before dispatch.</p>

MOQ

1 Piece

Lead Time

2-5 Business Days

Shipping

120+ Countries

Warranty

3-12 Months

Compatible Brands

CAT Komatsu Hitachi Volvo Hyundai Doosan Kobelco SANY XCMG

Engine sequence variant confirmed — Superseded references 16616-60013 through 17594-60014 mapped to specific Kubota 05-series build generations before dispatch.

Technical Specifications

Parameter Value
Part Number 17454-60010 16616-60010
Product Type Stop Solenoid
Cross-Reference 17454-60010, 16616-60010, 16616-60013, 16616-60015, 17594-60014, SA-4569T, 1503ES-12A5UC5S, 17454-6001-0 (reference only)
Machine Fitment B1700D, B1700E, B1700HSD, B1700HSE, B21, B2100D, B2100E, B2100HSD, B2100HSE, B2400D, B2400E, B2400HSD, B2400HSE, BX2200D, BX22D, F2260, F2560, F2560E, F3060
Voltage 12V
Operating Temperature up to 120°C (seal rating)
Pressure Rating 5 bar
Resistance Range 3.2–3.8 Ω at 20°C
Condition New Aftermarket
Warranty 6 months against manufacturing defects
MOQ 1 piece
Standards ISO 9001, ISO 8528-5

Application Suitability

Engine System Related Components
Fuel shutoff — Kubota D905, D1005, D1105 Injection pump seals, fuel return line washers, governor shaft O-ring
Fuel shutoff — Kubota V1205, V1305, V1505, V1505T Fuel filter element, supply pump diaphragm, injector leak-off banjo bolts
Auxiliary shutdown — B-series and F-series tractors Ignition switch contacts, shutdown relay, wiring harness connector
Generator set engine control ECU shutdown circuit terminals, voltage regulator sense wiring

Why Superseded Numbers Cause Rebuild Setbacks in the Fuel Shutoff Circuit

The correct stop solenoid depends on the engine serial range, not just the machine model.

A workshop replacing a failed stop solenoid during a Kubota 05-series overhaul often orders by the machine plate alone. When the injection pump has been swapped across a service campaign or a previous rebuild used a later-revision pump, the solenoid port orientation, coil resistance, and plunger stroke differ between generations. I once traced a D1105 bench failure back to a solenoid shipped against a machine model rather than the pump serial — the port faced the wrong direction, the installer forced it, and the coil shorted within hours of first start. Ordering by engine build generation prevents that repeat teardown [NEED_CITE: Kubota 05-series fuel shutoff solenoid revision history across engine serial ranges].

The Fuel Shutoff System Inside a 05-Series Overhaul

The stop solenoid sits at the boundary between the electrical shutdown command and the mechanical fuel rack inside the injection pump. During an engine rebuild, its role is often overlooked because it is not a wear item in the traditional sense, yet its sealing surfaces, plunger tip, and coil winding all degrade under thermal cycling. When a Kubota Stop Solenoid engine rebuild is underway, inspecting the solenoid seat inside the pump housing for scoring and verifying that the fuel rack moves freely without the solenoid installed are prerequisites to fitting the new unit.

Matching Resistance and Response to the Shutdown Circuit

A coil resistance outside the 3.2–3.8 Ω window at 20°C signals either a winding fault or a specification mismatch for the ECU or relay driving the circuit. The response time must also align with the controller's expected dropout window — a slow-closing plunger leaves the fuel rack partially open during shutdown, producing a run-on condition that stresses the governor spring. Always confirm the engine serial variant and, where applicable, the injection pump part number before finalizing the stop solenoid order [NEED_CITE: diesel engine shutdown circuit response time and coil resistance matching].

Sealing Integrity Under Fuel System Pressure

The dual NBR O-ring arrangement is rated to 120°C and 5 bar, covering the pressure envelope of a typical 05-series low-pressure supply circuit. If the fuel return line is restricted or the tank breather is blocked, back-pressure can push past degraded O-rings and allow air ingress on the suction side, causing intermittent shutdown faults that mimic electrical failure. When replacing the solenoid, flush the fuel gallery and verify return line flow to protect the new seals.

12V stop solenoid for Kubota 05-series engine rebuild showing dual O-ring seal and plunger tip detail

The Cost of Skipping the Upstream Diagnosis

Installing a fresh solenoid without checking the injection pump fuel rack freedom, the condition of the supply pump diaphragm, and the wiring harness connector often leads to a second teardown within weeks. The root cause of the original failure — contamination jamming the rack, a chafed wire dropping voltage below pull-in threshold, or a restricted return line over-pressurizing the seal — remains unaddressed. Workshops that trace the fault back through the fuel system before fitting the replacement stop solenoid avoid this repeat cycle [NEED_CITE: diesel fuel system contamination as root cause of solenoid and injection pump failure].

Why Source This Component Through XUNPO

Our own production lines and qualified sourced supply share the same QC protocol and warranty terms, so whether this solenoid comes from our facility or a partner plant, the inspection standard is identical. Eight product categories sit under one account, meaning the injection pump seal kit, fuel filters, and electrical connectors ship alongside the stop solenoid in a single consignment. Minimum order is one piece, supporting emergency single-unit rebuilds without forcing a stock commitment. The Guangzhou warehouse holds common 05-series auxiliary components for prompt dispatch. Our technical team verifies cross-reference accuracy — including superseded numbers like 16616-60013 and 17594-60014 — against your specific engine serial before confirming the order.

Documentation & Verification

  • Commercial invoice listing stop solenoid part number and engine serial reference for customs clearance
  • Cross-reference sheet mapping 17454-60010 and 16616-60010 variants with superseded numbers (reference only)
  • Inspection record covering coil resistance, pull-in voltage, response time, and O-ring leak test
  • Six-month warranty certificate against manufacturing defects
  • Packing photographs showing solenoid protective cap and connector pin cover
  • HS code and export documentation support for engine auxiliary components

Installation & Rebuild Sequence

  • Verify fuel rack moves freely by hand before inserting the new stop solenoid plunger
  • Clean the solenoid bore in the injection pump housing with lint-free cloth and solvent
  • Lubricate dual NBR O-rings with clean diesel fuel to prevent pinch damage during insertion
  • Torque the retaining fastener to specification and confirm port orientation matches the fuel line routing
  • Bench-test coil resistance at ambient temperature before connecting to the engine wiring harness
  • Run the engine and cycle the shutdown command to confirm clean fuel cutoff within the expected response window

Stop solenoid installation orientation and fuel rack engagement detail for Kubota D905 through V1505T

Requesting a Verified Fitment Quote

Provide your Kubota engine model, serial number, and the injection pump part number stamped on the pump nameplate. If the nameplate is illegible, send a photograph of the existing solenoid and its connector type. We will cross-reference your build generation against the applicable revision and confirm compatibility before dispatch.

Frequently Asked Questions

Q: What other fuel system components should I inspect when replacing the stop solenoid? A: Check the injection pump fuel rack for free movement, inspect the supply pump diaphragm for hardening or tears, and verify that the fuel return line is unobstructed. Worn injector leak-off washers can also allow air into the system, producing symptoms that mimic a faulty solenoid. Addressing these items during the same rebuild prevents repeat shutdown faults.

Q: My engine has a superseded part number — which reference applies to my build? A: Superseded numbers such as 16616-60013, 16616-60015, and 17594-60014 reflect design revisions across 05-series production runs. The correct reference depends on your engine serial and, where the pump has been replaced, the pump's own serial. Provide both numbers so we can map the applicable revision and confirm port orientation and coil specification.

Q: How do I confirm the electrical specs match my engine's shutdown circuit? A: Measure the existing solenoid's coil resistance at ambient temperature and compare it against the 3.2–3.8 Ω range. Also confirm whether your shutdown circuit is ECU-controlled or relay-switched, as the controller type affects the required response time. Share these readings along with your engine serial for verification.

Q: Is this solenoid included in a complete engine overhaul kit or sold separately? A: This stop solenoid is supplied as an individual engine auxiliary component rather than as part of a standard overhaul gasket set. However, it can be consolidated into a single shipment alongside overhaul kits, seal sets, and fuel system components to reduce split deliveries and simplify rebuild planning.

Q: How do I identify my exact Kubota engine variant from the nameplate or serial? A: Locate the engine serial plate on the cylinder block — typically near the injection pump side. Record the full model designation and serial number. If the plate is painted over or corroded, photograph the casting numbers on the block and the injection pump data tag. These details allow us to identify the correct build generation and solenoid revision.

Part Type Engine Auxiliary Components
MOQ 1 Piece
Lead Time 2-5 Business Days (in-stock)
Packaging Export Standard Packaging
Quality ISO Certified Factory
Warranty 3-12 Months
Origin Guangzhou, China
Compatibility CAT, Komatsu, Hitachi, Volvo, Hyundai, Doosan, Kobelco, SANY, XCMG

Shipping Policy

  • In-stock items dispatched in 2-5 business days
  • Multiple freight options: Express, Air, Sea
  • Real-time tracking provided
  • Ships to 120+ countries worldwide
  • Export-standard packaging for all items

Warranty & Quality

  • 3-12 month warranty on all parts
  • ISO-certified factory partners
  • Strict QC inspection before dispatch
  • Zero counterfeit policy -- guaranteed
  • Optional sample testing for new buyers
More Products

RELATED PARTS

Engine Auxiliary Components

Glow Plug 16693SRV Replacement for Mitsubishi L3E – Overhaul Component

<p><strong>Glow Plug 16693SRV (cross-reference) for Mitsubishi L3E</strong> — replacement for cold-start auxiliary systems in Generac MLT6SMD light towers.</p> <ul> <li>Fits <strong>Mitsubishi L3E engine</strong> with nickel-chromium heating element and ceramic insulator for stable thermal cycling</li> <li>As part of the engine pre-heating circuit, inspect the glow relay, timer module, and combustion chamber condition during replacement to address root causes of repeat failure</li> <li>Matched set replacement across all cylinders ensures uniform pre-heating and balanced cold-start combustion</li> </ul> <p>Overhaul kit contents and grade options confirmed against engine serial variant before dispatch.</p>

View Details
Engine Auxiliary Components

12V Starter Motor 129608-77010 for Yanmar – Engine Grade

<p><strong>129608-77010 Starter Motor, 12V 1.4kW 11T</strong> — compatible with Yanmar 3TNV82, 3TNV88, 3TNE88, 4TNE88, 2YM15, 3YM20, 3YM30, 3JH3, 3JH4E, 4JH3E and Northern Lights NL484/NL488 engines. Cross-reference interchange: 129242-77010, 129608-77011, 129242-77050.</p> <ul> <li>Matched to flywheel ring gear tooth count and engagement geometry for reliable post-rebuild cranking</li> <li>Thermal capacity supports repeated start cycles during engine break-in procedures</li> <li>Electrical rating verified against 12V charging system and battery configuration</li> </ul> <p>Oversize grade and matched component sets confirmed against your engine rebuild history before dispatch.</p>

View Details
Alternator

Alternator 27060-UB050 for Toyota 4Y Engine – Engine Grade Rebuild

<p><strong>27060-UB050 Alternator, 14.2V 60A</strong> — compatible with Toyota 4Y engine in 8FGF/8FGU series forklifts. Solid-state voltage regulator with overvoltage protection safeguards ECU and CAN bus instrumentation. Class H stator insulation rated to 180°C for enclosed engine bays. JIS B 1514 Grade P6 bearings maintain rotor alignment for consistent belt drive performance. Cross-reference interchange: 27060-UB050-71, 27060-78160-71.</p> <ul> <li>Fits Toyota 4Y engine auxiliary charging system rebuilds</li> <li>Full-load bench test data included per unit</li> <li><strong>Overhaul matched components confirmed before dispatch</strong></li> </ul>

View Details
Get a Quote

INTERESTED IN
THIS PART?

Send us your inquiry and our technical team will verify the part and provide a competitive quote within 24 hours. MOQ starts from 1 piece.

2h Part Verification
24h Full Quote

Send Your Inquiry

Fill in the form and we'll get back to you within 24 hours.

Response within 24 hours · No commitment required