Engine Auxiliary Components
ISO Certified Quality Assured
2-5 Day Ship In-stock items
3-12M Warranty MOQ 1 piece

Engine Grade Stop Solenoid 1502-12A2U1B2 | System-Matched for Woodward 12V

<p><strong>Stop Solenoid 1502-12A2U1B2</strong> for Woodward 12V engine shutdown control systems — 12V DC, IP67 sealed, high-permeability silicon steel core with precision-ground stainless steel plunger.</p> <ul> <li>Replacing this solenoid during electrical system overhaul? Inspect shutdown circuit wiring, relay condition, and controller output before installation to avoid repeat failures from undiagnosed root causes</li> <li>Cross-reference: 150212A2U1B2, 1500-2114, 15002114 (interchange reference only)</li> <li><strong>Sample available for functional testing</strong> before bulk commitment — verify voltage compatibility and mounting pattern with engine controller serial number first</li> </ul>

MOQ

1 Piece

Lead Time

2-5 Business Days

Shipping

120+ Countries

Warranty

3-12 Months

Compatible Brands

CAT Komatsu Hitachi Volvo Hyundai Doosan Kobelco SANY XCMG

Matched Sets Shipped Together — Every stop solenoid 1502-12A2U1B2 order includes verified cross-reference documentation and electrical test records matched to your Woodward 12V controller specifications.

Technical Specifications

Parameter Value
Part Number 1502-12A2U1B2
Product Type Stop Solenoid
Cross-Reference 150212A2U1B2, 1500-2114, 15002114 (reference only)
Machine Fitment Universal fit for Woodward 12V engine shutdown control systems
Voltage 12V DC
Operating Voltage Range 10.8V to 13.2V
Core Material High-permeability cold-rolled silicon steel
Plunger Material Precision-ground stainless steel (HRC 58–62)
IP Rating IP67
Dimensional Tolerance ±0.05 mm on mounting holes and stroke length
Surface Treatment Nickel plating (≥15 μm thickness)
Condition New Aftermarket
Standards ISO 9001:2015, SAE J1455
Warranty 3–12 months against manufacturing defects

Application Suitability

Engine System Related Components
Emergency stop circuits Shutdown relays, control wiring harnesses, circuit breakers
Routine shutdown protocols Key switches, ignition relays, timer modules
Generator shutdown systems Voltage regulators, overspeed protection modules, governor controllers
Industrial power units Engine controllers, fuel shutoff valves, alarm panels

Why a New Stop Solenoid Fails Within Weeks of Installation

The root cause usually sits upstream in the shutdown control circuit, not in the solenoid coil itself.

I worked on excavators and generators across Nigerian mine sites where stop solenoids burned out repeatedly. Crews replaced the unit, the engine started fine, and two weeks later the machine was back on the bench with a melted coil. The problem was voltage fluctuation from degraded relays or undersized wiring feeding the solenoid at levels outside the 10.8V–13.2V operating window. Replacing the solenoid without tracing the electrical fault simply puts a fresh component into the same destructive circuit [NEED_CITE: engine shutdown circuit voltage tolerance diagnostic procedures]. A proper engine electrical system overhaul addresses the wiring, relay contacts, and controller output before the new stop solenoid engine shutdown control rebuild component ever sees power.

Stop Solenoid 1502-12A2U1B2 wiring terminal and mounting pattern detail

The Shutdown Circuit as a System, Not a Single Part

A stop solenoid engine shutdown control rebuild job belongs to the broader engine safety and electrical system. When an engine rebuild shop or repair centre quotes this work, the solenoid sits alongside shutdown relays, control wiring, and the governor or engine controller that sends the signal. Mismatched components in that chain cause intermittent shutdowns or complete failure to cut fuel. Checking every node in the circuit before installation prevents repeat visits to the same machine.

Voltage Fluctuations and What They Reveal About Engine Wiring

The 10.8V to 13.2V operating range on this stop solenoid defines the window where the coil generates correct magnetic flux without overheating. Voltage dips below threshold mean the plunger may not fully retract, leaving the engine unable to shut down on command. Sustained voltage above range accelerates insulation breakdown in the coil winding. In my experience with quarry equipment and marine auxiliary generators, chronic over-voltage traced back to failing voltage regulators or corroded battery connections [NEED_CITE: electrical system voltage spike damage to solenoid coils]. Measuring actual voltage at the solenoid terminals under load, not just at the battery, tells the real story before the new part goes in.

Material Selection and Environmental Endurance

The high-permeability cold-rolled silicon steel core maintains stable magnetic flux across the full voltage range, which matters when alternator output varies under load changes. The precision-ground stainless steel plunger at HRC 58–62 resists galling from repeated impact cycles against the fuel rack or shutoff lever. IP67 sealing keeps moisture out of the coil cavity during washdown or rain exposure on site. Nickel plating at ≥15 μm thickness protects the housing from corrosion in coastal and high-humidity environments where bare steel would pit within months. The ±0.05 mm dimensional tolerance on mounting holes and stroke length ensures the plunger engages the fuel cutoff mechanism at the correct travel without binding or leaving a gap that prevents full shutdown [NEED_CITE: solenoid plunger stroke alignment and fuel cutoff verification].

Stop Solenoid plunger stroke and mounting hole dimensional check

What Happens When the Wrong Solenoid Goes In

Installing a stop solenoid with incorrect stroke length or mounting pattern means the plunger either fails to reach the fuel cutoff or jams against it. On a generator running unattended, that failure mode removes the only automatic shutdown protection against overspeed. In repair centres I have supported, an undersized coil burned open within days when fed from a 24V circuit through a dropping resistor that had itself degraded. The machine lost emergency stop capability without triggering any alarm, and the fault only surfaced during a scheduled test [NEED_CITE: generator overspeed protection failure modes]. Sourcing the correct specification and confirming the circuit voltage before installation eliminates these hidden risks.

Why Procurement Verification Matters Here

Our production and sourcing lines operate under the same QC protocol and warranty terms, so whether your stop solenoid comes from our own facility or a qualified partner, the test documentation is identical. We carry eight component categories under one account, meaning shutdown relays, wiring connectors, and associated electrical parts ship in a single consignment rather than arriving on different schedules. Guangzhou warehouse stock covers common shutdown components for fast dispatch. Our technical team confirms voltage compatibility, mounting pattern, and stroke length against your engine controller model and serial number before the order ships. We supply samples for functional fitment testing before you commit to bulk quantities.

Documentation & Verification

  • Commercial invoice and packing list with 1502-12A2U1B2 line items and HS codes
  • Cross-reference sheet mapping 150212A2U1B2, 1500-2114, and 15002114 (reference only)
  • Functional test record at rated 12V showing plunger stroke and coil resistance
  • Warranty terms covering manufacturing defects for 3–12 months from dispatch
  • Packing photographs showing sealed anti-static foam and protective carton
  • Customs documentation with correct HS code for solenoid valve classification

Installation & Rebuild Sequence

  • Verify shutdown circuit wiring continuity and relay contact resistance before connecting the new stop solenoid
  • Confirm mounting hole alignment and plunger stroke engagement with fuel cutoff lever at ±0.05 mm tolerance
  • Apply correct torque to mounting bolts to avoid housing distortion affecting plunger travel
  • Test shutdown function at both cold start and operating temperature before returning the engine to service
  • Measure voltage at solenoid terminals under load to confirm supply stays within 10.8V–13.2V range

Request a System-Matched Quotation

Provide your engine controller model, serial number, and any previous rebuild history so we can confirm the correct voltage specification and mounting configuration. If the original nameplate is worn or painted over, send a photograph of the existing solenoid and its wiring connector. We will return a compatibility confirmation along with related shutdown circuit components that should be inspected or replaced during the same service window.

Frequently Asked Questions

Q: What other shutdown circuit components should I inspect when replacing the stop solenoid? A: Check shutdown relays for contact pitting, measure wiring harness resistance end to end, and verify the engine controller output voltage under load. Corroded battery terminals and degraded dropping resistors are common sources of voltage fluctuation that destroy new solenoid coils within weeks of installation.

Q: How do I confirm the correct voltage and mounting pattern for my engine controller? A: Provide the engine controller model and serial number so we can cross-check the required voltage rating and mounting hole spacing. If the original label is unreadable, a photograph of the existing solenoid terminals and mounting flange allows our technical team to verify compatibility before shipping.

Q: Can I get a sample for functional testing before placing a bulk order? A: Yes, we supply single-piece samples so you can verify fitment, plunger stroke engagement, and electrical function on your specific engine controller before committing to larger quantities. Sample units ship under the same warranty and test documentation as production orders.

Q: What causes repeat stop solenoid failures after replacement? A: Repeat failures typically trace to unresolved upstream faults: voltage regulator malfunction, corroded wiring connections, or relay contact degradation pushing supply outside the 10.8V–13.2V operating window. Replacing the solenoid without diagnosing these circuit issues puts the new unit into the same destructive environment.

Q: How do I identify the correct part number when the original label is worn? A: Send a photograph of the solenoid body, wiring connector, and mounting pattern. Our team cross-references the physical characteristics against known Woodward 12V shutdown system configurations, including superseded numbers like 1500-2114, to identify the correct replacement regardless of label condition.

Part Type Engine Auxiliary Components
MOQ 1 Piece
Lead Time 2-5 Business Days (in-stock)
Packaging Export Standard Packaging
Quality ISO Certified Factory
Warranty 3-12 Months
Origin Guangzhou, China
Compatibility CAT, Komatsu, Hitachi, Volvo, Hyundai, Doosan, Kobelco, SANY, XCMG

Shipping Policy

  • ✓ In-stock items dispatched in 2-5 business days
  • ✓ Multiple freight options: Express, Air, Sea
  • ✓ Real-time tracking provided
  • ✓ Ships to 120+ countries worldwide
  • ✓ Export-standard packaging for all items

Warranty & Quality

  • ✓ 3-12 month warranty on all parts
  • ✓ ISO-certified factory partners
  • ✓ Strict QC inspection before dispatch
  • ✓ Zero counterfeit policy -- guaranteed
  • ✓ Optional sample testing for new buyers
More Products

RELATED PARTS

Alternator

12V 14A Alternator Replacement for Kubota 15531-64017 Powertrain

<p><strong>15531-64017 Alternator, 12V 14A</strong> with matched rectifier-regulator for Kubota B-Series engine charging systems.</p> <ul> <li>Supplied as a paired set so voltage regulation and ripple control work together across the full charging circuit</li> <li>Fits B1550, B1700, B2100, B2400, B7500, BX series and 50+ additional Kubota variants</li> <li>High-purity copper windings and aluminum housing rated for 85°C continuous ambient operation</li> </ul> <p>Cross-reference 15531-64017 verified against superseded numbers — matched charging components ship together for complete engine system rebuilds.</p>

View Details
Cushion Damper

Shock Absorber Rubber Vibration Mount for Dynapac CA51–CA702 Compaction Equipment

<p>Stop compaction equipment downtime caused by cracked, hardened, or misaligned vibration mounts — this <strong>Dynapac vibration mount</strong> delivers OEM-matched damping and precise mounting geometry for CA51–CA702 series rollers. Built to replace part numbers 358172 and 4700358172, it restores smooth operation and extends service life without the risk of counterfeit rubber compounds or inconsistent durometer specs.</p> <ul> <li>Exact fit for Dynapac CA51, CA512, CA610, CA702, SCA512, and all listed models — no guesswork on bolt spacing or bushing taper</li> <li>Engineered with 65±3 Shore A natural/synthetic rubber blend — critical for resisting heat-induced compression set in continuous-duty compaction cycles</li> <li>Ships from our Guangzhou warehouse in 2–5 working days, even for single-piece orders — no waiting weeks for OEM backorders</li> <li>Backed by XUNPO’s 6-month warranty against manufacturing defects and full technical verification before dispatch</li> </ul>

View Details
Engine Auxiliary Components

12V 9-Tooth Starter Motor for Nissan K15/K21/K25 Engines – Direct OEM Replacement

<p>Get your Nissan K15/K21/K25 back online fast — no more downtime waiting for OEM delays or risking counterfeit starters that fail mid-job. This <strong>12V 9 tooth starter motor for Nissan K15,K21,K25</strong> delivers instant, reliable cranking with true OEM-equivalent torque and CW rotation — exactly what your engine expects.</p> <ul> <li><strong>Plug-and-play fit</strong> for K15, K21, and K25 engines — verified against factory specs, not just part numbers</li> <li>Uses the correct 9-tooth pinion gear pitch and engagement depth — a critical detail many clones get wrong, causing grinding or premature flywheel wear</li> <li>Backed by XUNPO’s 6-month warranty and real-world testing before shipment — because “works out of the box” shouldn’t be rare</li> <li>In-stock in Guangzhou and ships in 2–5 working days, even for single pieces — no MOQ pressure when you need it now</li> </ul>

View Details
Engine Auxiliary Components

12V Stop Solenoid 3991167 for Cummins 4BT – Direct Replacement for Hyundai R130/R170

<p>Stop engine shutdowns before they cost you downtime — this <strong>12V stop solenoid 3991167 for Cummins 4BT</strong> delivers OEM-equivalent response time and holding force, so your Hyundai R130 or R170 cuts power cleanly every time.</p> <ul> <li>Fits Cummins 4BT engines without modification — no adapter plates or wiring hacks needed</li> <li>Verified 12V DC pull-in voltage (±0.5V) and 1.8A hold current — critical for reliable shutoff in high-heat cab environments</li> <li>Replaces 3991167, SA-4941-12, and 3964627 with identical mounting footprint and solenoid stroke length</li> <li>Ships from Guangzhou warehouse same day — no waiting weeks for OEM backorders</li> </ul>

View Details
Get a Quote

INTERESTED IN
THIS PART?

Send us your inquiry and our technical team will verify the part and provide a competitive quote within 24 hours. MOQ starts from 1 piece.

2h Part Verification
24h Full Quote

Send Your Inquiry

Fill in the form and we'll get back to you within 24 hours.

Response within 24 hours · No commitment required