Engine Auxiliary Components
ISO Certified Quality Assured
2-5 Day Ship In-stock items
3-12M Warranty MOQ 1 piece

Shutoff Solenoid Valve 6681513 | Matched Set for Bobcat Skid Steer

<p><strong>Shutoff Solenoid Valve 6681513 Stop Solenoid 12V</strong> — compatible with Bobcat skid steer and compact excavator models including 751, 753, 763, S150, S160, S175, T190, 331, 337.</p> <p>This solenoid serves as the electrical-to-fuel interface within the engine shutoff system, coordinating with the injection pump and wiring harness. Copper coil construction maintains stable 12V activation across engine bay temperature ranges, while precision-machined plunger housing preserves fuel seal integrity during rebuilds.</p> <ul> <li>Fits 751, 753, 763, 773, S150, S160, S175, S185, T190, 325, 331, 337, 341</li> <li>12V rated, heat-resistant insulation</li> <li>Cross-reference 6681513 (interchange reference only)</li> </ul> <p>Matched fuel system components ship together with grade and sizing verified against your engine rebuild history.</p>

MOQ

1 Piece

Lead Time

2-5 Business Days

Shipping

120+ Countries

Warranty

3-12 Months

Compatible Brands

CAT Komatsu Hitachi Volvo Hyundai Doosan Kobelco SANY XCMG

Matched Set Dispatch — Solenoid verified against engine serial variant before inclusion in a consolidated fuel system kit.

Technical Specifications

Parameter Value
Part Number 6681513
Product Type Stop Solenoid
Cross-Reference 6681513 (reference only)
Machine Fitment 751, 753, 763, 773, 5600, 7753, S150, S160, S175, S185, T190, 325, 328, 331, 334, 337, 341
Voltage 12V
Condition New Aftermarket
Warranty 3-12 months against manufacturing defects
Standard ISO 9001

Application Suitability

Engine System Related Components
Fuel Shutoff Control Injection pump, fuel lines, electrical harness connectors
Engine Start/Stop Circuit Ignition switch, relay, wiring harness terminals
Emergency Shutdown System ECU signal interface, fuel rack linkage
Scheduled Overhaul Complete fuel system seal kit, gasket set, filter elements

Why Engines Still Fail to Shut Down After Solenoid Replacement

The root cause often lives upstream in the signal path, not in the solenoid coil itself.

When an engine refuses to shut down cleanly or will not restart after a fuel system service, the 12V stop solenoid engine rebuild teams replace first is frequently not the failed component. The fault can originate from ECU signal interference, a degraded relay contact, or a harness connector that has corroded inside the insulation sheath. I have seen machines come back to the workshop twice because the diagnosis stopped at the solenoid terminal. Checking the full signal chain before teardown avoids the repeat visit [NEED_CITE: electrical diagnostic sequence for diesel engine shutoff circuits]. Across a mixed fleet, the machines that present the most stubborn shutoff faults tend to be those with the highest vibration exposure, where connector fretting accelerates beyond normal intervals.

12V stop solenoid engine rebuild component for Bobcat fuel shutoff system

Where the Stop Solenoid Sits in the Fuel Control System

The stop solenoid serves as the electrical-to-mechanical interface within the fuel delivery system. It receives a 12V signal from the ignition circuit and actuates a plunger that either permits or blocks fuel flow to the injection pump. During a 12V stop solenoid engine rebuild workflow, this component must be evaluated alongside the injection pump rack position and the harness connector integrity, because any fault in those adjacent systems will produce the same shutoff failure symptom.

Engine Serial Variants That Change the Fitment Picture

Different engine serial ranges within the same machine model can carry distinct fuel system configurations. A Bobcat S185 from an earlier production run may use a different connector pinout or plunger stroke length compared to a later unit, even though the base machine model is identical. We verify engine serial number and fuel system variant before confirming compatibility, because shipping by machine model alone has led to misfit parts on more than one occasion [NEED_CITE: engine serial variant differences in fuel shutoff solenoid specifications]. The copper coil winding and heat-resistant insulation are rated for sustained engine bay temperatures, but the physical interface must match precisely.

Reading the Specification Sheet Against Actual Operating Conditions

The 12V rating defines the nominal activation voltage, but in practice the charging system on a skid steer can push voltage higher during operation. The copper coil construction provides stable activation across this range without thermal degradation. The precision-machined plunger housing maintains fuel system seal integrity under repeated cycling, which matters because the solenoid actuates every time the engine starts and stops. Heat-resistant insulation around the coil winding prevents breakdown in the sustained high-temperature environment of an enclosed engine compartment, where ambient air movement is limited compared to open-frame equipment.

Stop solenoid plunger housing and electrical connector detail

What Happens When the Wrong Variant Goes In

A solenoid that physically threads into the housing but carries the wrong plunger stroke or connector pinout will either fail to seal the fuel passage or fail to open it fully. The result is an engine that cranks but will not start, or one that runs but cannot be shut off through the key switch. Diagnosing this after installation means pulling the unit back out, inspecting the fuel rack for damage from partial engagement, and then waiting for the correct part. For a rebuild shop with a machine occupying a bay, that repeat teardown represents lost capacity [NEED_CITE: cost of misdiagnosis in diesel fuel system component replacement].

How This Supply Chain Works for Rebuild Shops

Own production on selected fuel system lines and qualified sourced supply on the remainder operate under one account and one warranty, so a stop solenoid and its matched injection pump seals carry the same QC terms. Eight product categories allow a complete overhaul list to ship as one consignment rather than split across multiple vendors. Minimum order starts at one piece for emergency single-unit repairs. Guangzhou warehouse stock supports fast dispatch on common items, and part identification works from a part number, machine model, photograph, or nameplate image. Cross-reference verification covers superseded and alternate numbers, and sample supply is available for fitment confirmation before bulk commitment.

Documentation & Verification

  • Commercial invoice listing each fuel system component with individual line detail
  • Cross-reference sheet marking superseded solenoid numbers as reference only
  • Quality inspection record covering voltage activation test and plunger stroke measurement
  • Warranty terms specifying coverage period and manufacturing defect scope
  • Packing photographs showing solenoid connector protection during transit
  • HS code and customs documentation formatted for fuel system component classification

Installation & Rebuild Sequence

  • Inspect the injection pump mounting face and fuel passage for debris before inserting the new solenoid plunger assembly
  • Confirm electrical harness connector pins are clean and free of corrosion before mating to the solenoid terminal
  • Verify plunger stroke length against the specification for the specific engine serial variant before final tightening
  • Perform a bench activation test at 12V to confirm plunger travel before installing the solenoid into the fuel system housing
  • Run the engine through three complete start-stop cycles after installation to verify shutoff response timing

Requesting a Compatibility Check

Send the engine model, serial number, and any previous overhaul records so the correct fuel system variant can be confirmed. If the existing solenoid is still on the machine, a photograph of the connector and nameplate helps verify the cross-reference before shipping. For fleet-level overhaul planning, include the machine count and typical duty cycle to receive matched component recommendations.

Frequently Asked Questions

Q: What other fuel system components should be inspected when replacing this stop solenoid? A: The injection pump rack, fuel line fittings, harness connector terminals, and relay contacts should all be checked during the same service event. A worn rack or corroded connector will replicate the shutoff failure even with a new solenoid installed. Inspect these during the same teardown to avoid a second bay visit.

Q: Does this solenoid fit all engine serial variants for the listed Bobcat machine models? A: Not universally. Engine serial ranges within models like the S175 or 331 can carry different connector pinouts or plunger stroke lengths. Provide your engine serial number so we verify the exact variant before dispatch. This step prevents fitment issues that machine model alone cannot resolve.

Q: How do I confirm whether the solenoid or the injection pump is causing the shutoff failure? A: Apply 12V directly to the solenoid terminals with the engine off and listen for the plunger click. If the solenoid actuates but the engine still will not shut off when reconnected to the machine harness, the fault likely sits in the signal path or pump rack. This isolates the component before committing to a full teardown.

Q: What testing validates the solenoid before and after installation? A: Before installation, a bench test at rated voltage confirms plunger travel and return spring function. After installation, three consecutive start-stop cycles verify that the engine shuts down within the expected timeframe under normal operating temperature. Both steps should be documented in the quality record.

Q: Can I order matched fuel system overhaul components in a single consignment? A: Yes. Solenoids, seal kits, gasket sets, and filters ship together under one account with unified warranty terms. Consolidating the order into one shipment avoids split freight costs and ensures all components arrive before the rebuild begins, keeping the machine bay productive.

Part Type Engine Auxiliary Components
MOQ 1 Piece
Lead Time 2-5 Business Days (in-stock)
Packaging Export Standard Packaging
Quality ISO Certified Factory
Warranty 3-12 Months
Origin Guangzhou, China
Compatibility CAT, Komatsu, Hitachi, Volvo, Hyundai, Doosan, Kobelco, SANY, XCMG

Shipping Policy

  • ✓ In-stock items dispatched in 2-5 business days
  • ✓ Multiple freight options: Express, Air, Sea
  • ✓ Real-time tracking provided
  • ✓ Ships to 120+ countries worldwide
  • ✓ Export-standard packaging for all items

Warranty & Quality

  • ✓ 3-12 month warranty on all parts
  • ✓ ISO-certified factory partners
  • ✓ Strict QC inspection before dispatch
  • ✓ Zero counterfeit policy -- guaranteed
  • ✓ Optional sample testing for new buyers
More Products

RELATED PARTS

Engine Auxiliary Components

12V Stop Solenoid 3930658 | Overhaul Component for Cummins 4BT 6BT

<p><strong>3930658 Stop Solenoid, 12V</strong> — replacement for Cummins 4BT and 6BT engine fuel shutdown systems. This solenoid operates within the engine's electrical and fuel control circuit, where matched tolerances and coil consistency support reliable shutdown response during overhaul or system-level repair. - Copper coil windings rated for stable 12V magnetic force delivery - Hardened steel plunger with sealed housing to resist moisture and debris - Dimensional match to existing fuel injection mounting for direct fitment - Cross-reference: 3932529, SA-4756-12, SA-4891-12 (reference only) Overhaul kit contents and matched component lists verified before dispatch.</p>

View Details
Alternator

10044 → 1+0+0+4+4 = 9 9 mod 6 = 3 → [品牌/机型]-Compatible [品类词] – [站点修饰词] 第一层 xunpomachineryparts.com → Engine Grade / Rebuild Kit / Matched Set / Overhaul Component / Powertrain / System-Matched 9 mod 6 = 3 → Overhaul Component 12V Alternator 30-00423-00 for Carrier Genesis – Overhaul Component

<p><strong>30-00423-00 Alternator, 12V</strong> — replacement for Carrier transport refrigeration engines including CT2-29TV, CT3-44TV, Genesis R70/R90 and Maxima series. This unit sits within the engine auxiliary electrical system; matching alternator output to compressor start-up load and control board requirements prevents voltage drop faults. Cross-reference numbers such as 30-00409-64, 30-00363-00 and LS17139 correspond to different production batches and engine generations.</p> <ul> <li>Supplied with verified compatibility across listed Carrier models</li> <li>Overhaul component paired with belt, regulator and pulley checks</li> <li>Matched-set dispatch ensures all auxiliary electrical parts ship together</li> </ul>

View Details
Engine Auxiliary Components

Rebuild Kit Glow Plug Compatible with Perkins 402D-05 404D-15

<p><strong>185366250 / 185366220 Glow Plug Set for Perkins 402D-05 / 404D-15</strong>, M10×1.25 thread, 12V rapid heat cycle, matched to engine auxiliary cold-start system requirements.</p> <ul> <li>Replacing glow plugs in matched sets with ±3% resistance tolerance prevents uneven cylinder pre-heating, ECU fault codes, and incomplete combustion soot loading</li> <li>Voltage ramp rate and peak tip temperature aligned with Perkins 400-series ECU expectations to avoid tip burnout or hard-start cylinder scoring</li> <li>Adjacent system inspection recommended at replacement: glow plug relay, controller timing, wiring harness voltage drop, injector spray pattern, and crankcase oil condition</li> </ul> <p>Cross-reference part numbers 185366250, 185366220, NL-185366220, NL-185366250, SBA185366220 verified for superseded and alternate variants.</p> <p>Resistance and thermal ramp test records provided with each batch, matched sets shipped together for uniform cold-start performance across all cylinders.</p>

View Details
Engine Auxiliary Components

Engine Grade 12V Fuel Injection Pump Shutoff Solenoid AR90340 RE37089 RE62240

<p><strong>AR90340 RE37089 RE62240 Stop Solenoid 12V</strong> — replacement for John Deere, Perkins, Stanadyne/Roosamaster fuel injection pumps.</p> <ul> <li>Matches <strong>mechanical injection pump</strong> systems across 5.7L–7.3L variants; cross-reference verified for superseded numbers AR48219, AR51796, RE37089, RE62240</li> <li>Supplied with compatible overhaul seals and fuel line fittings for complete pump service; confirm engine serial and pump model to select correct plunger stroke and terminal type</li> <li>Overhaul kit contents verified item by item before dispatch</li> </ul>

View Details
Get a Quote

INTERESTED IN
THIS PART?

Send us your inquiry and our technical team will verify the part and provide a competitive quote within 24 hours. MOQ starts from 1 piece.

2h Part Verification
24h Full Quote

Send Your Inquiry

Fill in the form and we'll get back to you within 24 hours.

Response within 24 hours · No commitment required